ISO 13485 · CE CERTIFIED MEDICAL DEVICE DISTRIBUTOR +90 212 909 11 77 info@7medikal.com
NIPRO®

Brizio™ Oxygenator

Membrane oxygenator and venous reservoir with integrated cardiotomy filter — Adult

BRIZIO™ is an adult cardiopulmonary bypass solution that combines a venous reservoir with an integrated cardiotomy filter and an E8 synthetic-coated membrane oxygenator in a single system. It is designed for low priming volume, effective microbubble removal and high gas-transfer performance.

Brizio™ Oxygenator
READY TO USE

EtO-sterilized, preconnected and E8-coated set: venous reservoir, cardiotomy filter, oxygenator and heat exchanger in a single product.

INDICATIONS & USE

An integrated solution for adult cardiopulmonary bypass

BRIZIO™ is designed for oxygenating blood, removing carbon dioxide and controlling blood temperature in adult cardiopulmonary bypass (CPB) circuits, and for collecting, filtering and storing venous and cardiotomy blood.

  • Blood oxygenation and carbon dioxide removal during cardiopulmonary bypass in adult patients.
  • Collection, 40 µm filtration and storage of venous drainage and cardiotomy (suction) blood.
  • Blood temperature control during perfusion via the integrated heat exchanger.
  • Vacuum-assisted venous drainage (VAVD) in the sealed reservoir configuration.

Combining the reservoir, cardiotomy, oxygenator and heat exchanger in a single preconnected set simplifies perfusion circuit setup and reduces blood contact with foreign surfaces.

Brizio™ Oxygenator — indications
PERFORMANCE DATA

Tested gas and heat transfer performance

237 mL
Low priming volume
Oxygenation chamber priming volume (catalog value).
7 L/dk
Maximum blood flow
Operates across a 1.0 – 7.0 L/min blood flow range.
0,71
Heat exchanger performance factor
At 4 L/min blood flow and 15 L/min water flow.
O₂ transfer (mL/min) vs. blood flow rate
O₂ transfer (mL/min) vs. blood flow rate
CO₂ transfer (mL/min) vs. blood flow rate
CO₂ transfer (mL/min) vs. blood flow rate
Oxygenation chamber pressure drop ΔP (mmHg)
Oxygenation chamber pressure drop ΔP (mmHg)
Heat exchanger performance (in vitro, 15 L/min water flow)
Heat exchanger performance (in vitro, 15 L/min water flow)
Source: Nipro BRIZIO™ product catalog (CA058(EN) Rev. A) · In vitro tests with bovine blood under ISO 7199 / EN 12022 conditions.
E8 SYNTHETIC COATING

A biocompatible coating that reduces blood–surface contact

NIPRO uses the E8 synthetic coating developed by Toyobo. This polyethylene glycol-based, 100% synthetic (non-biological) functional copolymer coats the oxygenation chamber, polypropylene fibers and heat exchanger, preventing direct contact of blood with plastic surfaces. In liquid phase it forms a non-rigid, homogeneous and continuous membrane.

Brizio™ Oxygenator — mechanism of action

100% Synthetic Copolymer

A non-biological, polyethylene glycol-based structure with high molecular freedom and aliphatic chain length, offering lasting biocompatibility.

Less Thrombus and Aggregation

In a 3-hour extracorporeal animal perfusion at 7 L/min, E8-coated fibers showed markedly less thrombus formation and platelet aggregation than uncoated fibers.

Lower Complement Activation

In studies, E8-coated BRIZIO™ showed lower activation of the C3 and CH50 inflammatory markers compared with other coatings on the market (p < 0.01, n = 8).

ARCHITECTURE

An integrated circuit designed for the perfusionist

The venous reservoir, separate-chamber cardiotomy system, top-down flow oxygenation chamber and heat exchanger work together for safe, bubble-free, low-volume perfusion.

01
Progressive-Filtration Reservoir and Cardiotomy
VENOUS RESERVOIR
Progressive-Filtration Reservoir and Cardiotomy
  • 4000 mL hard-shell reservoir; the 40 µm filter retains unwanted particles and microbubbles.
  • The venous drainage and vent line route blood directly to the outlet without contact with the reservoir's plastic surfaces.
  • The separate-chamber cardiotomy system prevents continuous contact of suction blood with venous blood at levels below 1000 mL.
  • Volume scale in 10 mL steps, with high-contrast yellow marks down to the 200 mL minimum level.
02
Top-Down Flow Oxygenation Chamber
OXYGENATOR
Top-Down Flow Oxygenation Chamber
  • Blood flows from top to bottom; bubbles and microbubbles are retained at the top of the chamber and kept out of the arterial line.
  • A quick-positioning clamp lets the chamber rotate 360° on its axis, giving free placement of venous inlet, arterial outlet, recirculation and gas lines.
  • 391 thin-walled, polished stainless steel tubes in the heat exchanger; turbulence-free, near-physiological flow.
03
Articulated Holder Arms
HOLDER
Articulated Holder Arms
  • Bi-articulated arms allow flexible positioning of the oxygenator relative to the patient and the heart-lung machine.
  • Three holder models: Advanced (SUP-001BRZ), Intermediate (SUP-002BRZ) and Basic (SUP-003BRZ).
TECHNICAL SPECIFICATIONS

Key technical parameters

Reservoir · Blood storage capacity
4000 mL
Reservoir · Minimum operating volume
200 mL
Reservoir · Blood flow range
1.0 – 7.0 L/min
Reservoir · Maximum cardiotomy blood flow
5.0 L/min
Reservoir · Cardiotomy filter element
40 µm
Reservoir · Maximum rated pressure
6.66 kPa (50 mmHg) / −20 kPa (−150 mmHg)
Reservoir · Negative / positive pressure relief valve
−200 ± 5 mmHg / +65 ± 5 mmHg
Reservoir · Venous inlet port
1/2" (12.7 mm)
Reservoir · Reservoir outlet port
3/8" (9.5 mm)
Reservoir · Cardiotomy inlet ports
6 × 1/4" (6.4 mm)
Oxygenator · Hollow fiber membrane
Microporous polypropylene
Oxygenator · Membrane surface area
Approx. 2.2 m²
Oxygenator · Static priming volume
< 270 mL
Oxygenator · Blood flow range
1.0 – 7.0 L/min
Oxygenator · Heat exchanger
Stainless steel, approx. 0.2 m²
Oxygenator · Maximum pressure (blood inlet)
650 mmHg (87 kPa)
Oxygenator · Maximum pressure (water inlet)
1000 mmHg (134 kPa)
Oxygenator · Blood inlet / outlet ports
3/8" (9.5 mm)
Oxygenator · Gas inlet / outlet ports
1/4" (6.4 mm) / 3/8" (9.5 mm)
Oxygenator · Water ports
Hansen quick connect, 1/2" (12.7 mm)
Temperature probe
Yellow Springs type
Coating
NIPRO E8 synthetic coating
Sterilization
Ethylene oxide (EtO)
Oxygenator models
BRZ+12000A · BRZ+12005A · BRZ+12305A · BRZ+12345A
Holder models
SUP-001BRZ (Advanced) · SUP-002BRZ (Intermediate) · SUP-003BRZ (Basic)